← MSHA accidents

FALL OF ROOF OR BACK

220042040027 · 07/19/2004 · Solar Sources Underground L L C

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Felson Bowman
Operator
Solar Sources Underground L L C
Mine
1202103

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #2 ENTRY, AT THE #8 X-CUT LOCATED IN THE PANEL 8 EAST RETURN AIR COURSE. THE ROOF FALL WAS 40'LONG X 18'WIDE X 8'HIGH. SUPPLEMENTAL SUPPORTS HAVE BEEN INSTALLED AROUND THE ROOF FALL & THE ROOF FALL WILL NOT BE CLEANED UP. INITIALLY BOLTED WITH 4'FULLY GROUTED ROOF BOLTS. THE ROOF MATERIAL CONSISTED OF LAMINATED BLACK SHALE & A SAND STONE.

Source

Authoritative
MSHA Open Government Data
Machine