← MSHA accidents
HOISTING
220042100057
· 07/25/2004 · Consol Pennsylvania Coal Company
Details
Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years
Operator
Controller (parent)
CONSOL Energy Inc
Operator
Consol Pennsylvania Coal Company
Mine
3607416
Narrative
THE EAST FINLEY ELEVATOR WAS DOWN FOR MORE THAN 30 MINUTES WITH PEOPLE ON THE ELEVATOR. THERE WAS NO DAMAGE TO THE ELEVATOR. THE ELEVATOR OUTAGE WAS CAUSED BY THE LIMIT SWITCH FOR THE GOVERNOR ROPE - HAD TRIPPED BECAUSE THE NEW ROPE HAD STRETCHED.
Source
Authoritative
MSHA Open Government Data
Machine
JSON-LD
·
Markdown