A ROOF FALL OCCURRED IN THE 1 SOUTH #2 ENTRY IN THE INTERSECTION OF CROSSCUT #32 UP TO INTERSECTION OF CROSSCUT #33 MEASURING 80 FT X 19 FT X 6FT - 9FT. THE AREA WAS MINED IN APRIL 2004 AND SUPPORTED WITH 6FT TENSION REBAR BOLTS & 9FT MEGA BOLTS. THIS FALL WAS CAUSED BY A HIDDEN SLIP IN THE MINE ROOF.