# ELECTRICAL
> MSHA accident `220042250051` · 07/03/2004 · Tarmac Florida Inc
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Barge/Boat/Dredge/Towbarge/Towboat/Leach operator, Riverman, Deck hand
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 0
- **Mine experience:** 18 years
## Operator
- **Controller:** Titan Cement International S A
- **Operator:** Tarmac Florida Inc
- **Mine:** [0800635](https://api.ai-analytics.org/mine/0800635)
## Narrative

OPERATOR, CHANGING A FUSE, RECEIVED AN ELECTRIC SHOCK. HE DID NOT USE A HOT STICK OR GLOVES. HE DID NOT RECEIVE ANY INJURIES BUT WAS SENT TO THE DOCTOR TO BE CHECKED OUT. HE DID NOT USE LOCK-OUT TAG-OUT PROCEDURES.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*