A roof fall was found in the No. 8 entry INTAKE, the fall measures 35' long, 18' wide, 6' thick. The fall occurred 2000' outby the 002 section and was due to laminated rock and coal streaks in the strata. The area was developed Mar 04 with 5' torque tension roof bolts. The fall did not impeade travel/ventilation and NO injuries occurred. The area was resupported and barricaded.