A roof fall in the 6 North Panel in #3 entry in the intersection of cross-cut #37 and extending part of the way through the pillar-line towards cross-cut #38 measuring 60ft. x 18ft. x 5ft. This area was mined in August 2004 and supported with 5ft. fully grouted roof bolts. This fall was caused by a hidden slip in the mine roof.