A ROOF FALL OCCURRED IN ENTRY #2 MAIN SOUTH EAST AT SURVEY STATION 5+60. THE FALL MEASURED 30' LONG X 18' WIDE X 9' THICK. THIS AREA HAD BEEN BOLTED WITH 9' DOUBLE LOCKS AND 6' FULLY GROUTED RESINS BOLTS. ALL APPROACHES TO THIS AREA WILL BE TIMBERED.