# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220042530034` · 08/27/2004 · Tata Chemicals (Soda Ash) Partners LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** General Chemical; Andover Group
- **Operator:** Tata Chemicals (Soda Ash) Partners LLC
- **Mine:** [4800155](https://api.ai-analytics.org/mine/4800155)
## Narrative

BLEEDER IGNITION IN 2 ROOM OF PANEL FM02. A DAMAGED CABLE TO THE RIGHT GATHERING HEAD MOTOR. IT WAS DETERMINED THAT WAS THE PROBABLE CAUSE OF THE BLEEDER IGNITION.

---