# ELECTRICAL
> MSHA accident `220042570071` · 09/03/2004 · Heidelberg Materials Northeast LLC
## Details
- **Degree of injury:** DYS AWY FRM WRK & RESTRCTD ACT
- **Classification:** ELECTRICAL
- **Accident type:** Contact with hot objects or substances
- **Occupation:** Superintendent
- **Activity:** Electrical maintenance
- **Injury source:** FLAME,FIRE,SMOKE,NEC
- **Nature of injury:** BURN OR SCALD (HEAT)
- **Body part:** ARM, MULTIPLE PARTS
- **Days lost:** 11
- **Mine experience:** — years
## Operator
- **Controller:** Hanson PLC
- **Operator:** Heidelberg Materials Northeast LLC
- **Mine:** [3600139](https://api.ai-analytics.org/mine/3600139)
## Narrative

EE was changing wires in breaker panel for the Simplicity screen when electrical wire came in contact with another wire or metal box creating a ball of fire.  Heat from ball of fire caused burns.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*