A roof fall occured in the 6 North Panel in #1 entry in the inby pillarline of cross-cut #61 and extending through the intersection of cross-cut #63 measuring 90ft. x 19ft. x 5ft. This area was mined in August 2004 and supported with 5ft. fully grouted roof bolts. This fall was caused by an undetected slip.