← MSHA accidents

FALL OF ROOF OR BACK

220042640084 · 09/15/2004 · PENNAMERICAN COAL L P

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Robert E Murray
Operator
PENNAMERICAN COAL L P
Mine
3608525

Narrative

DURING A WEEKLY AIRCOURSE EXAM A FALL WAS FOUND 30' OUTBY STATION #39 IN #1 ENTRY OF SWM. THE FALL MEASURED 40' LONG, 18'-20' WIDE AND 5' HIGH. THE AREA WAS BOLTED WITH 48"" FULLY-GROUTED RESIN BOLTS WITH 6"" X 6"" AND 6"" X 16"" PLATES. NO MEN OR EQUIPMENT WERE INVOLVED. VENTILATION WAS NOT INTERRUPTED.