A roof fall occurred in the 2 North Panel in #1 entry in the intersection of cross-cut #40 measuring 19ft. x 19ft. x 5ft. This area was mined in August 2004 and supported with 5ft. fully grouted roof bolts. This fall was caused by an undetected slip.