While examining return with msha inspector ee. I found a fall in #3 entry x-cut 900' into 3 SE but we also found a fall adjacent to this area in #1 entry which impeded our travel. Area had cutter present when mined & was bolted with 42"" resin bolts. 6' resin bolts & cables were installed as supplements. This is an abandoned portion of the mine. it is now dangered off with timbers.