AN UNINTENTIONAL ROOF FALL OCCURRED IN #2 ENTRY OF 3 EAST 1 RIGHT SECTION AT 2+50. THE FALL OCCURRED IN THE INTERSECTION ON #2 ENTRY AT 2+50. THE AREA WAS BOLTED WITH 43"" FULLY GROUTED RESIN BOLTS. FALL WAS 50' LONG BY 20' WIDE AND 5' HIGH. FALL DAMAGED THE MINER & BOLTER CABLE. NO PERSONS WERE INJURED. VENTILATION WAS NOT INTERRUPTED. AREA WAS TIMBERED OFF & ABANDONED.