A ROOF FALL OCCURRED OUTBY UNIT #2. THE FALL IS IN THE #3 ENTRY AT 11 X-CUT. THE FALL DAMAGED AN INTAKE STOPPING. THE APPROACHES TO THE FALL WERE RE-SUPPORTED AND A NEW STOPPING BUILT. THE FALL IS 20' WIDE X 55' LONG X 10' HIGH. BOLTED WITH 10' POINT ANCHOR ROOF BOLTS. WILL NOT BE CLEANED UP.