# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220043200011` · 11/01/2004 · PCS Phosphate Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Potash Corp Of Saskatchewan
- **Operator:** PCS Phosphate Company Inc
- **Mine:** [3100212](https://api.ai-analytics.org/mine/3100212)
## Narrative

An operator initiated start-up procedures on the #5 calciner.  He started the exhaust and tempering blowers.  An ignition occurred.  While the unit was down, bunker C had vaporized and collected in the upper calciner compartment.  When tempering air was added, it provided additional oxygen to an already hot compartment resulting in the ignition.  Estimated cost to repair, $30,000.

---