A roof fall occured in the South West Vent Entries at crosscut #18 in the #6 and #7 entries. The fall measured 70' X 20' X 6'. This area was mined in August of 2000 and was supported with 6' tension rebar bolts and timbers. The fall was caused by an undetected slip.