# FALL OF ROOF OR BACK
> MSHA accident `220043360021` · 11/28/2004 · Solar Sources Underground L L C
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Felson  Bowman
- **Operator:** Solar Sources Underground L L C
- **Mine:** [1202103](https://api.ai-analytics.org/mine/1202103)
## Narrative

ROOF FALL OCCURRED ON THE MAIN NORTH ENTRIES IN #6 ENTRY BETWEEN #69 AND 70 CROSSCUT. ROOF FALL WAS 40' X 18' X 5-6'. ROOF FALL WILL BE CLEANED UP. INITIALLY THE AREA WAS BOLTED WITH 4' FULLY GROUTED ROOF BOLTS AND METAL STRAPS BETWEEN ROOF BOLT PATTERNS. ROOF MATERIAL CONSISTED OF LAMINATIONS OF BLACK SHALE AND SAND STONE.

---