A roof fall occurred between #3 and #4 entry of the 2nd MNE at survey station 1 and 40. The fall measured 40' long by 18' wide by 10' thick. This area had been bolted with 9' double lock and 6' fully grouted resin bolts. All approaches have been timbered.