← MSHA accidents

HOISTING

220043420015 · 11/22/2004 · FMC Corp

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
FMC Corp
Operator
FMC Corp
Mine
4800152

Narrative

The hoistman checking overtravel shutoffs when the overtravel (at mine level) not reset. Overtravel on lilly controller still operable. Electrician went underground, reset the magntic overtravel switch by running magnet over the switch, it worked fine from then on. There was no damage, physical or electrical and the hoist was put back in regular operation at 5:00pm.