Roof fall in face and intersection of #3 entry, break 2, 3-2 xcut to the left, 1-left mains development. Intersection and faces were ok at pre-shift inspection. No one on section during shift due to work needed outside. Upon returning to faces, fall found. Roof material found laying against back of bolter parked in 3-2 break 2 xcut to left.