# FALL OF ROOF OR BACK
> MSHA accident `220050140025` · 01/13/2005 · ICG-Illinois, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG-Illinois, LLC
- **Mine:** [1102664](https://api.ai-analytics.org/mine/1102664)
## Narrative

A ROOF FALL OCCURRED AT 10:15AM ON 1/13/05 AT X-CUT 86 ENTRY 3 JMAINSOUTH. FALL WAS IN 4-WAY INTERSECTION THAT HAD BEEN MINED 1/4/91. FALL 20' LONG X 30' WIDE X 10' HIGH. AREA WAS SUPPORTED WITH 8' FULL RESIN BOLTS AND PROPS. NO INJURY OCCURRED BUT MAIN LINE BELT WAS COVERED UP. FALL WILL BE CLEANED UP.

---