# HOISTING
> MSHA accident `220050260011` · 01/23/2005 · Cargill Salt 
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Cargill Inc
- **Operator:** Cargill Salt 
- **Mine:** [3000663](https://api.ai-analytics.org/mine/3000663)
## Narrative

The pressure switch that powers the brake motor on and off, was out of adjustment.  This caused the brake system on the hoist to lock up, and we could not release the breaks.  Down time was 17 hours used to trouble shoot and adjust pressure switch.  Hoist back in service 1/24/05 at 10am.

---