Intersection fell in at 19 block, #7 heading, 1 right section. Top gray laminated shale & little streaks of sandstone intermixed. Cover of 370' - 400'. 3-way intersection. Area bolted with 6' bolts & supplemented with 9' install II bolts. Fall will not be cleaned up. Moved sect. from this area.