# FALL OF ROOF OR BACK
> MSHA accident `220050340050` · 01/16/2005 · Consol of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol of Kentucky Inc
- **Mine:** [1518589](https://api.ai-analytics.org/mine/1518589)
## Narrative

An unintentional roof fall occurred on the 001-0 (west) section in the #4 entry (belt entry) spad #2613. Size: 4'-5'H x 60'L x 18'-20'W; had been supported with 4' fully grouted resin bolts. No injuries, no equipment caught, ventilation was not interrupted. Fall has been cleaned up.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*