# FALL OF ROOF OR BACK
> MSHA accident `220050450014` · 02/10/2005 · KenAmerican Resources Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** KenAmerican Resources Inc
- **Mine:** [1517741](https://api.ai-analytics.org/mine/1517741)
## Narrative

A roof fall occurred in the 1 South, #8 entry in one-third the intersection of cross-cut #36 and extending in the pillarline 6ft. towards cross-cut #37. The fall measured approximately 12ft. x 19ft. x 6ft.-9ft. Six foot tension rebar bolts and 9 foot mega bolts were used to support the area. An undetected slip was determined to be the cause of the fall.

---