AN UNPLANNED ROOF FALL OCCURRED IN THE #3 ENTRY (BELT ENTRY) OF SOUTH MAINS, 1 XCUT INBY SURVEY STATION #8. ROOF FALL WAS APPROXIMATELY 10' HIGH, 20' WIDE, 35' LONG. ROOF FALL DID NOT AFFECT ANY EQUIPMENT OR VENTILATION. AREA WAS BOLTED WITH 5' FULLY GROUTED RESIN BOLTS WITH 10' CABLE BOLTS INSTALLED AS SUPPLEMENTAL SUPPORTS ACCORDING TO THE APPROVED ROOF & RIB CONTROL PLAN.