A roof fall occurred in the 2 Main North at cross-cut #20 in the intersection of #2 entry. The fall measured 20ft. x 19ft. x 6ft. Six foot tension rebar bolts and square timbers were used to support the area. An undetected slip was determined to be the cause of the fall. This area was mined in December 2000.