# FALL OF ROOF OR BACK
> MSHA accident `220050600025` · 02/28/2005 · Bluff Spur Coal Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Cumberland Resources Corporation
- **Operator:** Bluff Spur Coal Corporation
- **Mine:** [4405559](https://api.ai-analytics.org/mine/4405559)
## Narrative

A ROOF FALL WAS DISCOVERED IN #2 ENTRY (1 BREAK INBY SURVEY STATION #4481) ABOUT 1200' OUTBY THE MMU003-0. THE FALL WAS IN AN INTERSECTION AND MEASURED 30' LONG X 20' WIDE X 10' HIGH. THERE WERE NO INJURIES OR EQUIPMENT INVOLVED, VENTILATION WAS NOT AFFECTED. THE FALL WILL NOT BE CLEANED UP. THE AREA WAS BOLTED WITH 5' RESIN GROUTED BOLTS, SUPPLEMENTED WITH 8' BOLTS

---