A roof fall occurred in a worked-out area of the 1LMS-2L3L-1R panel in entry #5 at crosscut 11. Cause of the fall was a geological slip in the mine roof. Addl. mine roof had been cut during normal mining operations & the area supported. Mine roof averaged 10 to 11 feet in height in this area, when it is normally around 6.