A ROOF FALL WAS FOUND AT X-CUT 267 ENTRY 7 MAIN SOUTH. AREA HAD BEEN MINED OCT. 1997, AND WAS SUPPORTED WITH 8' FULL RESIN BOLTS. FALL WAS APPROX. 20' WIDE X 30' LONG X 10' HIGH. NO INJURY OR PROPERTY DAMAGE RESULTED. FALL WAS ON MARKED ROUTE FOR WEEKLY ESCAPEWAY. ESCAPEWAY WILL BE REROUTED.