NORTH 4 BELT, 5 ENTRY, 64 BLOCK, MMU 004, 4 WAY INTERSECTION. 30' X 30' X 18'. SUPPORT: 6' 3/4"" RESIN BOLTS, ROOF MATS, CABLE BOLTS, CABLE TRUSS BOLTS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORT INSTALLED AROUND FALL. FALL WILL BE CLEANED UP, CLEAN UP PLAN POSTED