# FALL OF ROOF OR BACK
> MSHA accident `220051250036` · 05/03/2005 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

ROOF FALL HAS OCCURRED AT THE #43 Xcut ON THE SOUTH MAINS ""A"" BELTLINE. FALL IS APPROX. 25 FT L X 48 FT W BY 8 FT H. THE AREA WAS BOLTED WITH 8 FT INSTALL II BOLTS & RESIN W/METAL STRAPS & WIRE SCREEN. FALL DID NOT AFFECT ESCAPEWAYS/VENT. CAUSE WAS FAILURE OF BEAM CREATED BY ROOF BOLTS. COMPLIANCE WITH RULES/REGS,PROTECTIVE EQUIP, MINING EQUIP/SYSTEMS NOT A FACTOR.

---