A roof fall was found during the preshift for midnight shift. This fall was 3 x-cuts out by the working face of #1 entry of 3 south belt at station 5073. The area was bolted with 3' resin bolts and no separations were detected during mining. Also no breaks were detected while rebolting immediately adjacent to the fall with 6' resin bolts. Area cribbed and dangered off.