# FALL OF ROOF OR BACK
> MSHA accident `220051470007` · 05/25/2005 · Anker West Virginia Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Anker Group Inc
- **Operator:** Anker West Virginia Mining Company Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

Unintentional roof fall in H Mains, No. 7 entry, inby spad 10398.  The fall was discovered by General Mine Forman, at 7:15 AM.  Fall measured approximately  80'L X 7' H X 18' W.  The entry was previously supported with 5' torque tension roof bolts when developed 08/03.  There is 400' of cover in this area.  All approaches to the fall were protected with posts

---