DISCOVERED A ROOF FALL IN #6 ENTRY, ONE BLOCK FROM THE FACE ON THE 002 SECTION. THE FALL IS 9'H X 17'W X 20'LONG. IT WAS A 3WAY INTERSECTION. IT HAD BEEN BOLTED WITH 6'RESIN BOLTS & SPOT BOLTED WITH 9'INSTALL BOLTS. THE AREA WAS DANGERED OFF, BREAKERS SET & WILL NOT BE CLEANED UP. NO PERSONS OR EQUIPMENT WERE INVOLVED.