A ROOF FALL WAS DISCOVERED IN THE BLEEDER ENTRY, APPROX. 1300' FROM THE ACTIVE 001-0 SECTION. THE FALL MEASURED APPROX. 70'LONG X 14-16'WIDE X 0""-2' THICK AND WAS COMPOSED OF SANDSTONE. THE FALL BEGAN AT SURVEY STATION #2409 TO SURVEY STATION #2408.