← MSHA accidents

FALL OF ROOF OR BACK

220051640002 · 06/09/2005 · Long Branch Energy

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Long Branch Energy Corporation
Operator
Long Branch Energy
Mine
4609073

Narrative

Fall occur between a 3-way and 4-way intersection. The 4-way intersection was supported with 100 ton Heintzmann jacks and I-Beams with 4-100 ton pizza pan jacks on the side where the fall occured. Fall is 30 ft. long, 19 ft. wide by 5-6 ft. thick