A roof fall occurred in the 1 South in #8 entry in the pillar line between cross-cut #46 and cross-cut #47 measuring approximately 30ft. x 19ft. x 6ft. The area was supported by 6ft. tension rebar bolts. An undetected slip was determined to be the cause of the fall. The area was mined in April 2004.