# FALL OF ROOF OR BACK
> MSHA accident `220051810009` · 06/25/2005 · Anker West Virginia Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** Anker West Virginia Mining Company Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

An unintentional roof fall was discovered between spad numbers 9206 and 9048, Xct between 6 & 7 entry on E-7 Section.  Fall measured approx. 18'W X 80'L X 6'H.  Area was mined on 6/1/03 and was supported with 5' torque tension bolts.  Cover in this area is approx. 255'.

---