# FALL OF ROOF OR BACK
> MSHA accident `220051810014` · 06/29/2005 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4609073](https://api.ai-analytics.org/mine/4609073)
## Narrative

Roof fall in No. 6 entry between Spad No. 58 and No. 64, fall is 30'-40' long x 18' wide x 8'-10' thick.  Fall is in intake entry and air will be re-routed into No. 5 entry.  Reflectors and danger tags are hung.  Area will be breakered off with 100 ton Heintzmann, Pizza Jacks.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*