← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220051860039 · 06/25/2005 · Cumberland Coal Resources LP

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Foundation Coal Corporation
Operator
Cumberland Coal Resources LP
Mine
3605018

Narrative

A FRICTION CAUSED METHANE IGNITION, IT OCCURED ON THE LONGWALL PANEL 50 FACE BETWEEN 171 & 172 SHIELDS. METHANE WAS IGNITED BY FRICTION WHEN THE SHEARER STRUCK A PYRETIC INTRUSION LOCATED BETWEEN THE MAIN COAL SEAM & THE DRAW SLATE DIRECTLY ABOVE A DEGAS HOLE LOCATED 1 1/2 FEET FROM THE MINE BOTTOM. A RED/ORANGE FLAME, 2 - 3' LONG BURNED APPROX. 45 SECONDS BEFORE EXTINGUISHED.

Source

Authoritative
MSHA Open Government Data
Machine