← MSHA accidents

FALL OF ROOF OR BACK

220051920075 · 06/30/2005 · Consol Of Kentucky Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Of Kentucky Inc
Mine
1517720

Narrative

AN UNINTENTIONAL FOOR FALL OCCURRED IN THE #4 ENTRY (BELT) INBY SPAD #9398 3 SOUTH MAINS. SIZE ESTIMATED TO BE 160' L X 18-20' H. THE AREA HAD BEEN SUPPORTED WITH 5' TORQUE TENSION BOLTS WITH SUPPLEMENTAL SUPPORT CONSISTING 10' AND 16' ROPE BOLTS. NO INJURIES, BELT LINE CAUGHT, VENTILATION WAS NOT INTERRUPTED. FALL WILL BE CLEANED UP.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown