# FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
> MSHA accident `220051990015` · 07/12/2005 · Long Branch Energy
## Details
- **Degree of injury:** DYS AWY FRM WRK & RESTRCTD ACT
- **Classification:** FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
- **Accident type:** Struck by rolling or sliding object
- **Occupation:** Utility man, Errand boy, Service truck operator
- **Activity:** Roof bolter, NEC
- **Injury source:** CAVING ROCK,COAL,ORE,WSTE
- **Nature of injury:** MULTIPLE INJURIES
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** 26
- **Mine experience:** 0.63 years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4604955](https://api.ai-analytics.org/mine/4604955)
## Narrative

Employee came to roof bolter to bolt in place of regular operator who left sick.  He started to install first row of bolts, when rib rolled striking injured's left side.

---