0N 07/13/05, AN UNINTENTIONAL ROOF FALL OCCURRED ALONG THE 3RD MAIN WEST AT CROSS CUT #140, BETWEEN THE #4 AND #4 ENTRIES. THIS ROOF FALL WAS LOCATED IN A CROSS CUT AND WAS SUPPORTED WITH 6' POINT ANCHOR ROOF BOLTS, THE ROOF FALL MEASURED 30' X 18' X 7' AND THE ROOF FALL WILL NOT BE CLEANED UP