A roof fall occurred in the 5 North Panel in #8 entry starting in the pillarline inby cross-cut 63 and extending through the pillarline outby cross-cut 65. The fall measured approximately 70ft. x 19ft. x 5ft. The area was supported by 5ft. fully grouted roof bolts. The area was mined in July 2005. A hidden slip was determined to be the cause of the fall.