# FALL OF ROOF OR BACK
> MSHA accident `220052060075` · 07/12/2005 · T.J.S. Mining, Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Thomas J  Smith
- **Operator:** T.J.S. Mining, Inc.
- **Mine:** [3609159](https://api.ai-analytics.org/mine/3609159)
## Narrative

An unplanned roof fall occurred in the #2 entry of south mains (mmu 001-0) at our No. 5 mine. Fall is located 2 x-cuts inby survey station #74. Fall area is approximately 20' wide, 25' long, 9' to 10' high. Area bolted with 42"" fully grouted resin bolts according to the approved roof control plan. Fall will be cleaned up. Area posted and dangered off.

---