# HOISTING
> MSHA accident `220052090045` · 07/21/2005 · Consolidation Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consolidation Coal Company
- **Mine:** [4404856](https://api.ai-analytics.org/mine/4404856)
## Narrative

The page portal service elevator overtraveled due to a bad electrical relay. The elevator was down for 20 hours, from 8:00 PM on 7/21 until 4:00 PM on 7/22/05. The relay was replaced, the elevator was tested and the service cage was put back into service. There were no people on the service elevator at the time of the incident.

---