# FALL OF ROOF OR BACK
> MSHA accident `220052200004` · 08/03/2005 · Anker West Virginia Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** Anker West Virginia Mining Company Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

Unintentional roof fall discovered on 8/3/05.  Location of fall was:  #7 Belt inby station 9257, #4 Entry.  Area was mined 10/03.  Depth of cover is approx. 250'.  Was previously supported with 5' torque tension roof bolts.  Fall measured 6'H X 18'WX30'L.  The fall will not be cleaned.  No injuries.

---