A ROOF FALL WAS FOUND BY PRESHIFT EXAMINER AT 6:00AM ON 8/13/2005. FALL IS LOCATED BETWEEN SEAL 1 AND 2 MAIN NORTH. FALL MEASURED 50'X17'X5' HIGH. AREA WAS MINED NOVEMBER 1982 AND HAD BEEN SUPPORTED WITH 8' FULL RESIN BOLTS. FALL WILL BE CLEANED UP AND RESUPPORTED. NO INJURY OR PROPERTY DAMAGE RESULTED